Thermo Scientific™ Eutech™ CyberScan DO 600 Dissolved Oxygen Meter

For quick, accurate dissolved oxygen checks in laboratories, field and schools.

Marca:  Thermo Scientific™ 01X419502

Codice prodotto. 10747114

  • 1658.25€ / Pezzo

Effettua il per acquistare questo articolo Hai bisogno di un conto web ? Registrati oggi stesso!

Esplora altre offerte speciali
Questo articolo non è restituibile. Consulta la politica di reso

Descrizione

Descrizione

Measures oxygen concentration up to 90.00mg/L and Saturation up to 600.0%. Mega-storage space saves up to 500 data sets stamped with time and date – Perfect for GLP-compliant researches. Salinity, temperature and pressure compensation – accurate even under varying conditions. Comprehensive one-glance-tells-all screen with intelligent screen prompts. Cal-due alarm on real-time clock ensures periodic calibration updates. IP67 waterproof design for applications in harsh environments. Auto-logging function automatically records up to 500 data sets stamped with date and time–Great for GLP-compliant researches. LED-RS232 and IrDA Wireless Communication for direct Meter-to-PC data transfer. Convenient 2-point calibration with step-by-step calibration guide. Galvanic, so you don't have to wait for meter to warm up.

Features

Dissolved Oxygen

  • Range: 0.00 to 90.00mg/L or ppm
  • Resolution: 0.01mg/L or ppm
  • Accuracy: ±0.2mg/L

% Saturation

  • Range: 0.0 to 600.0%
  • Resolution: 0.1%
  • Accuracy: ±2 %

Temperature

  • Range: 0.0 to 50.0 °C (32 to 122 °F)
  • Resolution: 0.1 °C (0.1 °F)
  • Accuracy: ±0.3 °C (±0.5 °F)
  • Compensation: ATC /mTC (0.0 to 50 °C)

Salinity Correction

  • Range: 0.0 to 50.0 ppt
  • Resolution: 0.1 ppt
  • method: Automatic correction aftermanual input

Pressure Correction

  • Range: 450 to 825mmHg (59.9 to 109.9 kPa)
  • Resolution: 1mmHg (0.1 kPa)
  • method: Automatic correction with inbuilt sensor

Calibration

  • 2 Point (0%, 100%)
  • Operating Range
  • to 50.0 °C (32 to 122 °F)

Probe Type

  • Galvanic

Date/Time Stamping

  • Yes

memory

  • 500 data sets (GLP-compliant format)

Special Functions

  • Auto-Hold; Auto Power-Off after 2 - 30minutes (user-preset); Stability Indicator; Self-diagnosticsmessages

Power

  • 4 x 1.5 'AA' batteries (>400 hours) or 9V DC adapter, 500mA
TRUSTED_SUSTAINABILITY
Specifica

Specifica

DO 600 meter with 10-ft cable electrode, ECDOHANDYNEW, DAS software, power adapter & carrying kit case.
32°F to 122°F
0 mg/L to 90 mg/L
Suggerimenti di prodotto

Suggerimenti di prodotto

Videos
SDS
Documenti

Documenti

Certificati
Offerte speciali

Offerte speciali

Correzione del contenuto del prodotto

Fornite il vostro feedback sul contenuto del prodotto compilando il modulo sottostante.

Titolo del prodotto

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.

Grazie per averci aiutato a migliorare il nostro sito web. Il vostro feedback è stato inviato