Learn More
Thermo Scientific™ Pierce™ Gaussia Luciferase Flash Assay Kit
Sfoglia Tutto Thermo Scientific ProdottiDescrizione
The Thermo Scientific™ Pierce Gaussia Luciferase Flash Assay Kit provides researchers with the most sensitive assay for transcriptional activity of regulatory elements in mammalian cell culture media and whole cell lysate.
This Flash Assay Kit contains reagents for measuring the activity of Gaussia luciferase in mammalian cell culture media and lysates. When used with Thermo Scientific Gaussia Luc Vectors, the kit provides an extremely sensitive bioluminescent reporter assay system for secreted or intracellular detection of promoter or pathway activity. Gaussia luciferase is highly secreted into the cell culture media, allowing for live cell monitoring of reporter activity. The signal produced by Gaussia is considerably greater than signal from either firefly or Renilla luciferases assayed under similar conditions.
Highlights:
Sensitive – 1000 times greater sensitivity allows utilization of smaller numbers of cells
Cost effective – highest sensitivity assays result in decreased reagent consumption
Secreted luciferase – allows real-time assays and kinetic studies without destroying cells
Time-saving – assays using secreted luciferases require minimal sample handling
Automation-friendly – amenable to high throughput screens
Convenient – contains a universal cell lysis buffer and optimized flash assay reagent
Safe – allows one to perform non-radioactive assays
Includes:
Cell lysis buffer, reaction buffer and substrate
Requires:
Gaussia luciferase and luminometer or other instrument capable of monitoring luminescence, such as Thermo Scientific Luminoskan Ascent and Varioskan Flash Microplate Readers
Recommended for:
Promoter studies for analyzing cis- regulatory elements and trans-acting factors; Drug screening; siRNA and miRNA screening; Multiplexed assays to study off-target effects; Secretory pathway / protein localization reporter assays; Signal transduction pathway analysis; RNA splicing studies
Specifica
Specifica
| Tipo | Assay Kit |
| Bersaglio | Luciferase, Gaussia Luciferase |
| Sufficiente per | 100 Luciferase Assays |
| Quantità | 100 Reaction Kit |
| Content And Storage | Sufficient For: 100 luciferase assays in microplate wells • Gaussia Flash Assay Buffer, 5 mL (store at 4°C) • 100X Coelenterazine, 50 μL (store at -80°C) • Luciferase Cell Lysis Buffer (2X), 6 mL (store at room temperature) Kit may be stored at -80°C, or individually at indicated temperatures. |
| Saggio | Reporter Enzyme, Luciferase Reporter Assay |
| Compatible Cells | Mammalian Cells |
| Metodo di rilevamento | Bioluminescence |
| Da utilizzare con (apparecchiatura) | Luminometer (Microplate) |
| Formato | 384-well plate, 96-well plate |
| Vedi altri risultati |
Sicurezza e movimentazione
- Pierce Gaussia Luciferase Flash Assay Kit
- Pericolo
- Tossicità acuta Categoria 3
- Liquido infiammabile Categoria 2
- Tossicità specifica per organi bersaglio (esposizione singola) Categoria 1
- H225-Liquido e vapori facilmente infiammabili.
- H301-Tossico se ingerito.
- H311-Tossico per contatto con la pelle.
- H331-Tossico se inalato.
- H370-Provoca danni agli organi.
- P210-Tenere lontano da fonti di calore, superfici riscaldate, scintille, fiamme e altre fonti di innesco. Vietato fumare.
- P241-Utilizzare impianti elettrici/di ventilazione/d'illuminazione/ a prova di esplosione.
- P260-Non respirare la polvere/i fumi/i gas/la nebbia/i vapori/gli aerosol.
- P280-Indossare guanti/indumenti protettivi/Proteggere gli occhi/il viso.
- P301+P310-IN CASO DI INGESTIONE: contattare immediatamente un CENTRO ANTIVELENI/un medico/
- P303+P361+P353-IN CASO DI CONTATTO CON LA PELLE (o con i capelli): togliere immediatamente tutti gli indumenti contaminati. Sciacquare la pelle/fare una doccia.
- P304+P340-IN CASO DI INALAZIONE: trasportare l'infortunato all'aria aperta e mantenerlo a riposo in posizione che favorisca la respirazione.
- P403+P235-Conservare in luogo fresco e ben ventilato.
- P501b-Smaltire il prodotto/recipiente in conformità con le disposizioni locali/regionali/nazionali/internazionali.
- MIXTURE LIST-Contiene: methanol
For Research Use Only. Not for use in diagnostic procedures.
Fornite il vostro feedback sul contenuto del prodotto compilando il modulo sottostante.