missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ Pierce™ Gaussia Luciferase Glow Assay Kit

Codice prodotto. 12152240 Sfoglia Tutto Thermo Scientific Prodotti
Click to view available options
Quantità:
100 Reaction Kit
1000 Reaction Kit
Dimensione della confezione:
Pezzo
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso

Codice prodotto. 12152240

Marca: Thermo Scientific™ 16161

Effettua il per acquistare questo articolo Hai bisogno di un conto web ? Registrati oggi stesso!

Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso

Obtain bright and stable bioluminescence signal (half-life greater than 1 hour) in the presence of Gaussia luciferase reporters

The Thermo Scientific™ Pierce Gaussia Luciferase Glow Assay Kit provides an extremely bright and stable bioluminescence signal (half-life greater than 1 hour), especially in the presence of Gaussia-Dura luciferase reporter.

The Thermo Scientific Pierce Gaussia Luciferase Glow Assay Kit provides a sensitive bioluminescence system to determine expression of a gene of interest with a luciferase reporter. The extremely bright and stable bioluminescence signal (half-life greater than 1 hour) is produced in the presence of the Gaussia-Dura luciferase reporter due to oxidation of the luciferase substrate coelenterazine (Figure 1). Gaussia luciferase is a 20 kDa protein from the marine copepod, Gaussia princeps, that has greater protein stability and signal brightness than firefly and native Renilla luciferase. The bioluminescent enzyme is highly secreted into the cell culture media, allowing for live cell monitoring of reporter activity. Light output generated by the luciferase reaction can be correlated to the amount of Gaussia luciferase protein produced and used to determine the activity of the promoter driving Gaussia expression.

Features of the Gaussia Luciferase Glow Assay Kit:
Sensitive—highly sensitive detection of Gaussia luciferase activity
Stable—increased signal stability
Simple—does not require a luminometer with injectors
Compatible—assay reagents compatible with other Gaussia luciferases
Automation-friendly—amenable to high throughput assays
Convenient—contains a universal cell lysis buffer and optimized glow assay reagent
Safe—allows one to perform non-radioactive assays

When used with Thermo Scientific Gaussia-Dura Luc Vectors, the kit provides an extremely sensitive bioluminescent reporter assay system for detection of secreted or intracellular luciferase activity from promoter or pathway activation with extended signal stability. The light output generated by the luciferase reaction (emission maximum of 485 nm) indicates that Gaussia luciferase was transcribed. This light emission can be correlated to the amount of luciferase protein produced, which in turn is proportional to the activity of the promoter for Gaussia luciferase expression and indicates that the regulatory region of the target gene was active. This reaction does not require adenosine triphosphate (ATP) or other cofactors. The kit includes cell lysis buffer, reaction buffer and substrate and can be used to detect the activity of any Gaussia luciferases or derivatives that use coelenterazine as a substrate.

The Gaussia Luciferase Glow Assay Kit requires:
Gaussia luciferase and luminometer or other instrument capable of monitoring luminescence, such as Thermo Scientific Varioskan LUX Microplate Readers.

Applications of the Gaussia Luciferase Glow Assay Kit:
• Promoter studies for analyzing cis- regulatory elements and trans-acting factors
• Drug screening
• siRNA and miRNA screening
• Multiplexed assays to study off-target effects
• Secretory pathway/protein localization reporter assays
• Signal transduction pathway analysis
• RNA splicing studies

The Gaussia-Dura gene used in the Thermo Scientific Gaussia-Dura Luc Vectors is derived from the wild type Gaussia gene and provides equally bright but more stable light output. The Gaussia Glow Assay Kit reagent yields a Gaussia-Dura luciferase reaction with glow-type kinetics that provides a lower intensity but longer-duration signal allowing for higher sample throughput. This glow-type assay with a prolonged luminescence signal does not require reagent injectors and is recommended for luminometers without injectors or for applications requiring batch processing of samples.

TRUSTED_SUSTAINABILITY

Specifica

Tipo Assay Kit
Bersaglio Luciferase, Gaussia Luciferase
Sufficiente per 1000 Luciferase Assays
Quantità 1000 Reaction Kit
Content And Storage Sufficient For: 1000 luciferase assays in microplate wells
• Gaussia Glow Assay Buffer, 50 mL (store at 4°C)
• 100X Coelenterazine, 0.5 mL (store at -80°C)
• Luciferase Cell Lysis Buffer (2X), 60 mL (store at room temperature)

Kit may be stored at -80°C, or individually at indicated temperatures.
Saggio Reporter Enzyme, Luciferase Reporter Assay
Compatible Cells Mammalian Cells
Metodo di rilevamento Bioluminescence
Da utilizzare con (apparecchiatura) Luminometer (Microplate)
Formato 384-well plate, 96-well plate
Tipo di etichetta Enzyme Labeled
Substrate Properties Chemical Substrate
Tecnica Enhanced Chemiluminescence
Tipo di substrato Luciferase Substrate
Linea di prodotti Pierce
Substrato Coelenterazine
Promotore EF-1α
Vedi altri risultati Mostra meno risultati
compliance-icons compliance-icons compliance-icons compliance-icons
Identificativo prodotto
  • Pierce Gaussia Luciferase Glow Assay Kit
Avvertenza
  • Pericolo
Categoria di pericolo
  • Tossicità acuta Categoria 3
  • Tossicità acuta Categoria 4
  • Liquido infiammabile Categoria 2
  • Tossicità specifica per organi bersaglio (esposizione singola) Categoria 1
  • Tossicità specifica per organi bersaglio (esposizione singola) Categoria 2
Indicazioni di pericolo
  • H225-Liquido e vapori facilmente infiammabili.
  • H301-Tossico se ingerito.
  • H302-Nocivo se ingerito.
  • H311-Tossico per contatto con la pelle.
  • H319-Provoca grave irritazione oculare.
  • H331-Tossico se inalato.
  • H370-Provoca danni agli organi.
  • H371-Può provocare danni agli organi.
Consigli di prudenza
  • P210-Tenere lontano da fonti di calore, superfici riscaldate, scintille, fiamme e altre fonti di innesco. Vietato fumare.
  • P260-Non respirare la polvere/i fumi/i gas/la nebbia/i vapori/gli aerosol.
  • P264-Lavare accuratamente dopo l'uso.
  • P270-Non mangiare, né bere, né fumare durante l'uso.
  • P280-Indossare guanti/indumenti protettivi/Proteggere gli occhi/il viso.
  • P301+P310-IN CASO DI INGESTIONE: contattare immediatamente un CENTRO ANTIVELENI/un medico/
  • P301+P312-IN CASO DI INGESTIONE accompagnata da malessere: contattare un CENTRO ANTIVELENI/medico/
  • P302+P352-IN CASO DI CONTATTO CON LA PELLE: lavare abbondantemente con acqua/.
  • P308+P313-IN CASO di esposizione o di possibile esposizione, consultare un medico.
  • P330-Sciacquare la bocca.
  • P370+P378-In caso d'incendio: utilizzare per estinguere.
  • P403+P235-Conservare in luogo fresco e ben ventilato.
  • P501b-Smaltire il prodotto/recipiente in conformità con le disposizioni locali/regionali/nazionali/internazionali.
Informazioni supplementari
  • MIXTURE LIST-Contiene: methanol

For Research Use Only. Not for use in diagnostic procedures.

Correzione del contenuto del prodotto

Fornite il vostro feedback sul contenuto del prodotto compilando il modulo sottostante.

Titolo del prodotto

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.

Grazie per averci aiutato a migliorare il nostro sito web. Il vostro feedback è stato inviato