Thermo Scientific™ TraceGOLD™ TG-200MS GC Columns

Resolve compounds that phenyl and cyano phases cannot using a low-bleed GC column with an exceptionally inert phase.

610.00€ - 1306.58€

Specifica

Stationary Phase TraceGOLD™ TG-200 MS
Tipo USP G6
Temperatura max 320/340°C
Polarità Mid-Polar
Visualizza altre specifiche

Prodotti 7
Codice del prodotto Marca Lunghezza (sistema metrico) Diametro (sistema metrico) interno Spessore pellicola Prezzo Quantità e disponibilità  
Codice del prodotto Marca Lunghezza (sistema metrico) Diametro (sistema metrico) interno Spessore pellicola Prezzo Quantità e disponibilità  
15810900
Vedere i documenti
Thermo Scientific™
26084-1550
60 m 0.32 mm 0.25 μm
1306.58€
Pezzo
Spedizione stimata: 24-01-2025
per visualizzare lo stock disponibile
Aggiungi al carrello
 
10734647
Vedere i documenti
Thermo Scientific™
26084-1420
30 m 0.25 mm 0.25 μm
719.21€
Pezzo
Spedizione stimata: 14-02-2025
per visualizzare lo stock disponibile
Aggiungi al carrello
 
10524875
Vedere i documenti
Thermo Scientific™
26084-1430
30 m 0.32 mm 0.25 μm
791.55€
Pezzo
Spedizione stimata: 21-01-2025
per visualizzare lo stock disponibile
Aggiungi al carrello
 
10628525
Vedere i documenti
Thermo Scientific™
26084-2230
30 m 0.25 mm 0.5 μm Questo articolo non è attualmente disponibile o è stato dismesso.
La preghiamo di consultare la pagina del prodotto per individuare le possibili alternative.
N/A
10504115
Vedere i documenti
Thermo Scientific™
26084-2240
30 m 0.32 mm 0.5 μm
776.46€
Pezzo
Spedizione stimata: 10-01-2025
per visualizzare lo stock disponibile
Aggiungi al carrello
 
10016604
Vedere i documenti
Thermo Scientific™
26084-2960
30 m 0.25 mm 1 μm
733.31€
Pezzo
In stock
per visualizzare lo stock disponibile
Aggiungi al carrello
 
10743117
Vedere i documenti
Thermo Scientific™
26084-2970
30 m 0.32 mm 1 μm
791.70€
Pezzo
Spedizione stimata: 30-01-2025
per visualizzare lo stock disponibile
Aggiungi al carrello
 
Descrizione

Descrizione

Resolve compounds that phenyl and cyano phases cannot using the Thermo Scientific™ TraceGOLD™ TG-200MS GC Column. The TraceGOLD TG-200MS column has an exceptionally inert phase with selectivity and elution order optimized for difficult separations.

Engineered for Superior Performance
  • Polar phase, trifluoropropylmethyl polysiloxane solid phase to resolve compounds that phenyl and cyano phases cannot
  • Outstanding thermal stability and low bleed
  • Suitable for use with sensitive detectors including electrochemical detectors, nitrogen phosphorus detectors and mass spectrometers
  • Appropriate for use as a confirmation GC column
Applications:
  • Solvents
  • Fluorocarbons
  • Alcohols and ketones
  • Silanes
  • Glycols
A Leap Forward in Column Performance with Low Bleed and Superior Inertness
  • This low-bleed, stable column produces consistent results, and the low baseline noise enables improved limits of detection with enhanced resolution of low-level analytes.
  • Minimizing column bleed extends the column lifetime, leading to higher productivity.
  • Reducing column bleed increases reproducibility of the stationary phase over time, resulting in greater run-to-run and batch-to-batch reproducibility.
  • Superior inertness ensures excellent peak shape and sensitivity, especially for highly active or difficult-to-analyze compounds.
Recommended For:
  • Solvents
  • Fluorocarbons
  • Alcohols and ketones
  • Silanes
  • Glycols
  • Alternative Uses:
  • Herbicides
  • Organochlorine pesticides
  • Phenols
  • Similar To:
  • Rtx™-200MS
  • DB-200
  • DB-210
Specifica

Specifica

TraceGOLD™ TG-200 MS
G6
320/340°C
Mid-Polar
Videos
SDS
Documenti

Documenti

Product Certifications

Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Correzione del contenuto del prodotto

Fornite il vostro feedback sul contenuto del prodotto compilando il modulo sottostante.

Titolo del prodotto

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.

Grazie per averci aiutato a migliorare il nostro sito web. Il vostro feedback è stato inviato