Thermo Scientific™ OmniPac™ PAX-100 HPLC Columns
For optimizing separations of hydrophobic and halogenated anions, use this solvent-compatible anion-exchange column.
Pressione max | 4000 psi (275 bar) |
---|---|
Dimensione particelle | 8.5 μm |
Portata | 1 mL/min |
Tipo di colonna | Mixed Mode |
Fase stazionaria | Alkanol Quaternary Amine |
pH | 0 to 14 |
Da utilizzare con (applicazione) | Reversed Phase and Ion Exchange |
Diametro (sistema metrico) | 4 mm |
Tipo USP | L46 |
Dimensione del poro | 60 Å |
Materiale di impaccamento | Spherical, Microporous Polymer |
Thermo Scientific™ OmniPac™ PAX-500 HPLC Columns
When you need to separate anionic and neutral species in a single run, use this solvent-compatible mixed-mode column.
Pressione max | 4000 psi (275 bar) |
---|---|
Dimensione particelle | 8.5 μm |
Tipo di colonna | Mixed Mode |
Fase stazionaria | Alkanol Quaternary Amine |
pH | 0 to 14 |
Da utilizzare con (applicazione) | Reversed Phase and Ion Exchange |
Diametro (sistema metrico) | 4 mm |
Tipo USP | L50 |
Surface Area | 300 m²/g |
Dimensione del poro | 1200 Å |
Materiale di impaccamento | Spherical, Microporous Polymer |
Thermo Scientific™ OmniPac™ PCX-500 HPLC Columns
Separate cationic and neutral species in a single run using this solvent-compatible mixed-mode column.
Pressione max | 4000 psi (275 bar) |
---|---|
Dimensione particelle | 8.5 μm |
Tipo di colonna | Mixed Mode |
Fase stazionaria | Sulfonic Acid |
pH | 0 to 14 |
Da utilizzare con (applicazione) | Reversed Phase and Ion Exchange |
Diametro (sistema metrico) | 4 mm |
Tipo USP | L50 |
Dimensione del poro | 1200 Å |
Materiale di impaccamento | Spherical, Microporous Polymer |
Thermo Scientific™ OmniPac™ PCX-100 HPLC Columns
Separate hydrophobic cations using this solvent-compatible cation-exchange column.
Pressione max | 4000 psi (275 bar) |
---|---|
Dimensione particelle | 8.5 μm |
Tipo di colonna | Mixed Mode |
Fase stazionaria | Sulfonic Acid |
pH | 0 to 14 |
Da utilizzare con (applicazione) | Reversed Phase and Ion Exchange |
Diametro (sistema metrico) | 4 mm |
Tipo USP | L46 |
Dimensione del poro | 60 Å |
Materiale di impaccamento | Spherical, Microporous Polymer |
Thermo Scientific™ Dionex™ IonPac™ NS1 Analytical & Guard Columns
Achieve high-efficiency separations of hydrophobic, ionizable compounds with these polymeric-based, reversed-phase columns.
Portata | 1 mL/min |
---|---|
Tipo di colonna | Mixed Mode |
pH | 0 to 14 |
Thermo Scientific™ Dionex™ IonPac™ NS2 5μm Analytical & Guard Columns
Order the Thermo Scientific™ Dionex™ IonPac™ NS2 silica-based, high-efficiency, reversed-phase column for separation of charged analytes using mobile phase ion chromatography (MPIC) with suppressed conductivity detection.
Pressione max | 4000 psi (275 bar) |
---|---|
Dimensione particelle | 5 μm |
Portata | 0.5 to 1.0 (Recommended) |
Fase stazionaria | IonPac NS2 |
Temperatura (sistema metrico) | 20°C to 35°C |
pH | 2.0 to 9.5 |
Diametro (sistema metrico) | 4 mm |
Solventi | Compatible with 0 to 100% aqueous eluents. Compatible with most HPLC solvents, except THF 20% max. |
Surface Area | 300 m²/g |
Dimensione del poro | 120 Å |
Materiale di impaccamento | Spherical, high-purity, porous |