Learn More
Thermo Scientific™ Pierce™ Gaussia Luciferase Glow Assay Kit
Obtain bright and stable bioluminescence signal (half-life greater than 1 hour) in the presence of Gaussia luciferase reporters
141.00€ - 774.00€
Specifica
Tipo | Assay Kit |
---|---|
Bersaglio | Luciferase, Gaussia Luciferase |
Saggio | Reporter Enzyme, Luciferase Reporter Assay |
Compatible Cells | Mammalian Cells |
Metodo di rilevamento | Bioluminescence |
Codice del prodotto | Marca | Quantità | Prezzo | Quantità e disponibilità | |||||
---|---|---|---|---|---|---|---|---|---|
Codice del prodotto | Marca | Quantità | Prezzo | Quantità e disponibilità | |||||
12142240
|
Thermo Scientific™
16160 |
100 Reactions |
141.00€
Pezzo |
Effettua il login per acquistare questo articolo Hai bisogno di un conto web ? Registrati oggi stesso! | |||||
12152240
|
Thermo Scientific™
16161 |
1000 Reactions |
774.00€
Pezzo |
Effettua il login per acquistare questo articolo Hai bisogno di un conto web ? Registrati oggi stesso! | |||||
Descrizione
The Thermo Scientific™ Pierce Gaussia Luciferase Glow Assay Kit provides an extremely bright and stable bioluminescence signal (half-life greater than 1 hour), especially in the presence of Gaussia-Dura luciferase reporter.
The Thermo Scientific Pierce Gaussia Luciferase Glow Assay Kit provides a sensitive bioluminescence system to determine expression of a gene of interest with a luciferase reporter. The extremely bright and stable bioluminescence signal (half-life greater than 1 hour) is produced in the presence of the Gaussia-Dura luciferase reporter due to oxidation of the luciferase substrate coelenterazine (Figure 1). Gaussia luciferase is a 20 kDa protein from the marine copepod, Gaussia princeps, that has greater protein stability and signal brightness than firefly and native Renilla luciferase. The bioluminescent enzyme is highly secreted into the cell culture media, allowing for live cell monitoring of reporter activity. Light output generated by the luciferase reaction can be correlated to the amount of Gaussia luciferase protein produced and used to determine the activity of the promoter driving Gaussia expression.
Features of the Gaussia Luciferase Glow Assay Kit:
• Sensitive—highly sensitive detection of Gaussia luciferase activity
• Stable—increased signal stability
• Simple—does not require a luminometer with injectors
• Compatible—assay reagents compatible with other Gaussia luciferases
• Automation-friendly—amenable to high throughput assays
• Convenient—contains a universal cell lysis buffer and optimized glow assay reagent
• Safe—allows one to perform non-radioactive assays
When used with Thermo Scientific Gaussia-Dura Luc Vectors, the kit provides an extremely sensitive bioluminescent reporter assay system for detection of secreted or intracellular luciferase activity from promoter or pathway activation with extended signal stability. The light output generated by the luciferase reaction (emission maximum of 485 nm) indicates that Gaussia luciferase was transcribed. This light emission can be correlated to the amount of luciferase protein produced, which in turn is proportional to the activity of the promoter for Gaussia luciferase expression and indicates that the regulatory region of the target gene was active. This reaction does not require adenosine triphosphate (ATP) or other cofactors. The kit includes cell lysis buffer, reaction buffer and substrate and can be used to detect the activity of any Gaussia luciferases or derivatives that use coelenterazine as a substrate.
The Gaussia Luciferase Glow Assay Kit requires:
Gaussia luciferase and luminometer or other instrument capable of monitoring luminescence, such as Thermo Scientific Varioskan LUX Microplate Readers.
Applications of the Gaussia Luciferase Glow Assay Kit:
• Promoter studies for analyzing cis- regulatory elements and trans-acting factors
• Drug screening
• siRNA and miRNA screening
• Multiplexed assays to study off-target effects
• Secretory pathway/protein localization reporter assays
• Signal transduction pathway analysis
• RNA splicing studies
The Gaussia-Dura gene used in the Thermo Scientific Gaussia-Dura Luc Vectors is derived from the wild type Gaussia gene and provides equally bright but more stable light output. The Gaussia Glow Assay Kit reagent yields a Gaussia-Dura luciferase reaction with glow-type kinetics that provides a lower intensity but longer-duration signal allowing for higher sample throughput. This glow-type assay with a prolonged luminescence signal does not require reagent injectors and is recommended for luminometers without injectors or for applications requiring batch processing of samples.
Specifica
Assay Kit | |
Reporter Enzyme, Luciferase Reporter Assay | |
Bioluminescence | |
384-well plate, 96-well plate | |
Chemical Substrate | |
Luciferase Substrate | |
Coelenterazine |
Luciferase, Gaussia Luciferase | |
Mammalian Cells | |
Luminometer (Microplate) | |
Enzyme Labeled | |
Enhanced Chemiluminescence | |
Pierce™ | |
EF-1α |
Sicurezza e movimentazione
- Pierce Gaussia Luciferase Glow Assay Kit
Avvertenza
- Pericolo
Categoria di pericolo
- Tossicità acuta Categoria 3
- Tossicità acuta Categoria 4
- Liquido infiammabile Categoria 2
- Tossicità specifica per organi bersaglio (esposizione singola) Categoria 1
- Tossicità specifica per organi bersaglio (esposizione singola) Categoria 2
Indicazioni di pericolo
- H225-Liquido e vapori facilmente infiammabili.
- H301-Tossico se ingerito.
- H302-Nocivo se ingerito.
- H311-Tossico per contatto con la pelle.
- H319-Provoca grave irritazione oculare.
- H331-Tossico se inalato.
- H370-Provoca danni agli organi.
- H371-Può provocare danni agli organi.
Consigli di prudenza
- P210-Tenere lontano da fonti di calore, superfici riscaldate, scintille, fiamme e altre fonti di innesco. Vietato fumare.
- P260-Non respirare la polvere/i fumi/i gas/la nebbia/i vapori/gli aerosol.
- P264-Lavare accuratamente dopo l'uso.
- P270-Non mangiare, né bere, né fumare durante l'uso.
- P280-Indossare guanti/indumenti protettivi/Proteggere gli occhi/il viso.
- P301+P310-IN CASO DI INGESTIONE: contattare immediatamente un CENTRO ANTIVELENI/un medico/
- P301+P312-IN CASO DI INGESTIONE accompagnata da malessere: contattare un CENTRO ANTIVELENI/medico/
- P302+P352-IN CASO DI CONTATTO CON LA PELLE: lavare abbondantemente con acqua/.
- P308+P313-IN CASO di esposizione o di possibile esposizione, consultare un medico.
- P330-Sciacquare la bocca.
- P370+P378-In caso d'incendio: utilizzare per estinguere.
- P403+P235-Conservare in luogo fresco e ben ventilato.
- P501b-Smaltire il prodotto/recipiente in conformità con le disposizioni locali/regionali/nazionali/internazionali.
Informazioni supplementari
- MIXTURE LIST-Contiene: methanol
For Research Use Only. Not for use in diagnostic procedures.