WTW™ Turb™ Series 355 Portable Turbidity Meters
These portable turbidity meters are ideal for spot analysis in the field.
Dimensione campione | 15 mL |
---|---|
Tipo di display | LCD |
Warranty | 2 Years |
Include | Carrying case, 3 calibration standards (0.02- 10-1000 NTU), 2 empty 25 x 45m, 15mL sample volume cuvettes, cleaning tissues and 4 x AAA batteries |
Risoluzione | 0.01NTU from 1 to 9.99, 0.1 NTU from 10.0 to 99.9, 1 NTU from 100 to 1000 |
Tipo di batteria | 4 Micro (AAA) Alkaline Manganese |
Protezione IP | IP67 |
Tempo di risposta | 14 sec. |
Tipo | Portable Turbidity Meter |
Lunghezza (sistema metrico) | 70 mm |
Altezza (sistema metrico) | 48 mm |
Temperatura (sistema metrico) operativa | 0°C to 50°C |
Da utilizzare con (applicazione) | Used for spot analysis in the field - especially for all applications |
Peso (sistema metrico) | 1.22 kg |
Velp Scientifica™ TB1 Turbidimeter
Velp Scientifica™ TB1 Turbidimeter that measures the turbidity of aqueous samples simply and accurately.
WTW™ Turb™ Series 430 Portable Turbidity Meters
With an accuracy of 0.01 NTU or ±2% of the measured value; these portable turbidity meters are ideal for all applications including drinking water testing, environmental monitoring, laboratory reference measurements and process control.
Dimensione campione | 20 ml |
---|---|
Tipo di display | LCD |
Accuracy | 0.01 NTU o ±2% del valore misurato |
Warranty | 2 anni |
Lunghezza (sistema metrico) | 117 mm |
Altezza (sistema metrico) | 86 mm |
Temperatura (sistema metrico) operativa | Da 0 a 50 °C |
Da utilizzare con (applicazione) | Per applicazioni relative ad analisi di acqua potabile, monitoraggio ambientale, misurazioni di riferimento di laboratorio e controllo di processi |
Peso (sistema metrico) | 0.6 kg |
Risoluzione | 0.01 da 0.00 a 9.99, 0.1 da 10 a 99.90, 1 da 100 a 1100 |
Tipo di batteria | 4 x AA |
Protezione IP | IP67 |
Thermo Scientific™ Eutech TN-100 Turbidimeter Calibration Kit
Simple, display-prompted push-button calibration
Gli ordini eseguiti prima delle 14:00 saranno spediti oggi stesso. Gli ordini eseguiti dopo le 14:00 saranno spediti domani.
Per saperne di più
Thermo Scientific™ Torbidimetro Orion™ AQUAfast AQ3010
Generate an accurate turbidity reading quickly with the Thermo Scientific™ Orion™ AQUAfast AQ3010 Turbidity Meter
Thermo Scientific™ Eutech TN-100 Handheld Infrared Turbidity Meter Kit
Waterproof, portable, infrared Turbidity meter wtih extended range up to 2000 NTU, 0.01 resolution
Gli ordini eseguiti prima delle 14:00 saranno spediti oggi stesso. Gli ordini eseguiti dopo le 14:00 saranno spediti domani.
Per saperne di più
Lovibond™ ET 730 Portable Floc Tester
Flocculation Testers (also known as Jar Testers) are designed for a range of applications - such as testing the efficiency of flocculation or precipitation agents
Thermo Scientific™ Orion™ AQ4500 Turbidimeter
Utilize dual LED light sources and drinking water/wastewater methods approved for U.S. EPA regulatory reporting offered by this turbidity meter.
Tipo di display | LED |
---|---|
Metodi accettati ISO | ISO 7027 |
Tipo | Turbidity Meter |
Autonomia della batteria | 2500 Hours |
Descrizione | Turbidimeter and Calibration Kit |
Metodi approvati EPA | 180.1 |
Selezione intervallo automatica | Yes |
Certificazione/Conformità | US EPA approval for Drinking Water Reporting per 40 CFR Part 141, vol. 74, no. 147, Monday, August 3, 2009. Rules and regulations pg 38351-38356.EPA 180.1 and ISO 7032 |
Sorgente luminosa | LED, Multiple |
Thermo Scientific™ Orion™ AQUAfast™ AQ4500 Turbidity Meter Accessories
Ensure your turbidity meter has the accessories it needs, including turbidity vials, primary turbidity standards, Formazin turbidity standards, and more.
Lovibond™ ET 740 and ET 750 - Laboratory Floc / Jar Tester
Flocculation Testers (also known as Jar Testers) are designed for a range of applications - such as testing the efficiency of flocculation or precipitation agents
Tensione | 115/230 V |
---|---|
Tipo di display | Digital |
Tipo | Laboratory Flocculation Tester |
Requisiti elettrici | 115/230 V 50/60 Hz |
Altezza (sistema metrico) | 26.03 cm |
Larghezza (sistema metrico) | 34.2 cm |
Frequenza | 50/60 Hz |
Altezza (sistema imperiale) | 10.25 in. |
Da utilizzare con (applicazione) | For a range of applications such as testing the efficiency of flocculation or precipitation agents |
Tasti funzione | Timer |
Include | Power supply with US, EU and UK adapter, instruction manual |
Risoluzione | 1 Revolution |
Larghezza (sistema imperiale) | 13.5 in. |
Lovibond™ Infrared Lab Turbidimeter
Designed for quick and easy turbidity measurement in the laboratory
Hanna Instruments™ ISO Compliant Portable Turbidity Meters
High accuracy benchtop turbidity meter used to determine the turbidity of water and wastewater with high precision in the field as well as in the laboratory.
Hanna Instruments™ Portable Turbidity Meters
High accuracy benchtop turbidity meter that meets and exceeds the requirements of the ISO 7027 Method for turbidimetric measurements.
Grant Instruments™ Grant Bio™ Densitometer
Measures turbidity of cell suspensions in a variety of life science applications. Grant Instruments™ Densitometer is designed and factory calibrated to measure turbidity in the range of 0.5 to 4.0 McFarland units (DEN-1) 0.0 to >7.5 McFarland units (DEN-1B) with a small standard deviation.
Tensione | 12 V |
---|---|
Dimensione campione | ≥2 |
Requisiti elettrici | Input AC 120/230V 50/60 Hz Output DC 12 V |
Altezza (sistema metrico) | 75 mm |
Temperatura (sistema metrico) operativa | 4°C to 40°C |
Larghezza (sistema metrico) | 165 mm |
Dimensioni (L x P x A) | 115 x 165 x 75 mm |
Precisione | ±3% |
Peso (sistema metrico) | 0.7 kg |
Sorgente luminosa | LED |