Thermo Scientific™ Pierce™ Albumin Serum Depletion Kits

Optimize serum sample prep by depleting unwanted albumin and IgG serum proteins for protein-profiling methods using quality depletion kits.

Marca:  Thermo Scientific™ 85160

374.30 EUR valido fino al 2024-12-31
Usa il codice promo "22006" per avere il tuo prezzo promozionale.



 vedi altre versioni di questo prodotto

Codice prodotto. 13484309

  • 394.00€ / 24 reazioni
Spedizione stimata: 16-01-2025
per visualizzare lo stock disponibile
Esplora altre offerte speciali
Aggiungi al carrello
Questo articolo non è restituibile. Consulta la politica di reso

Descrizione

Descrizione

Concentrations of albumin and IgG can make up more than 70% of total serum proteins and often mask lower quantity proteins during protein-profiling experiments. Optimize your serum sample prep by removing albumin or IgG quickly and conveniently. By using our depletion kits to remove excess high-abundance serum proteins, less abundant proteins of interest can be easily detected by 2D electrophoresis and other protein profiling methods such as mass spectrometry.

Pierce Albumin/IgG Removal Kit

Optimized—microcentrifuge spin cup method is scaled for treating 10 μL human serum samples for 2D electrophoresis
Efficient—removes nearly all HSA and IgG, enabling low-abundance proteins to be detected in 2D gels
Fast—processes samples in less than 40 minutes
Scalable—use different amounts of affinity resin to match sample volume and concentration

The Thermo Scientific Pierce Albumin/IgG Removal Kit uses a classical mixture of Cibacron Blue Dye and Protein A resin for removal of albumin and IgG. The dye binds to albumin with good specificity, and Protein A binds to many species and subclasses of IgG. The Pierce Albumin/IgG Removal Kit is economical and can be used to treat samples from other species besides human (e.g., monkey, swine, rabbit). The kit is also scalable and sufficient to process 25 samples, each containing 600 μg of total serum protein (about 10 μL of serum).

Pierce Albumin Depletion Kit

Complete—includes optimized buffer and microcentrifuge spin columns to remove albumin quickly and conveniently from 10- to 50-μL samples
Adaptable—easy-to-dispense slurry improves performance, eases processing of multiple samples, and can be adapted to larger or smaller columns or 96-well filter plates
Compatible—removing excess albumin facilitates MS analysis or electrophoresis gel analysis of low-abundance serum proteins

The Thermo Scientific Pierce Albumin Depletion Kit resin is supplied as a 50% slurry. To prepare the depletion columns, 200 μL of slurry is dispensed into the supplied microcentrifuge spin columns to obtain 100 μL of settled beads to process 10 to 50 μL of serum sample in a single reaction. The kit has been optimized to bind human, porcine, and sheep albumin from serum samples. With a modification to the protocol, albumin from bovine, calf, goat, and rat can be removed with this method. The kit is not effective for removal of mouse albumin. Processed samples are ready for immediate downstream analysis by electrophoresis or MS applications.

TRUSTED_SUSTAINABILITY
Specifica

Specifica

Albumin Depletion Kit
Albumin Depletion Kit
Removing albumin from 24 human serum samples, 10 to 50 μL each
Plasma, Serum
Mass Spectrometry
Sample Enrichment, Sample Clean Up
Microcentrifuge, Mass Spectrometer
Pierce™
• Pierce Albumin Depletion Resin, 5 mL
• Binding/Wash Buffer, 11 mL
• Pierce Spin Columns, 24 columns

Store at 4°C.
Protein
Kit
24 Reactions
Suggerimenti di prodotto

Suggerimenti di prodotto

Videos
Sicurezza e movimentazione

Sicurezza e movimentazione

Identificativo prodotto
  • Pierce Albumin Serum Depletion Kits

Avvertenza
  • Attenzione

Categoria di pericolo
  • Lesione oculare grave/irritazione oculare Categoria 2

Indicazioni di pericolo
  • H319-Provoca grave irritazione oculare.

Consigli di prudenza
  • P264-Lavare accuratamente dopo l'uso.
  • P280-Indossare guanti/indumenti protettivi/Proteggere gli occhi/il viso.
  • P305+P351+P338-IN CASO DI CONTATTO CON GLI OCCHI: sciacquare accuratamente per parecchi minuti. Togliere le eventuali lenti a contatto se è agevole farlo. Continuare a sciacquare.
  • P337+P313-Se l'irritazione degli occhi persiste, consultare un medico.

Informazioni supplementari
  • MIXTURE LIST-Contiene: Sodium chloride

SDS
Documenti

Documenti

Certificati
Offerte speciali

Offerte speciali

Correzione del contenuto del prodotto

Fornite il vostro feedback sul contenuto del prodotto compilando il modulo sottostante.

Titolo del prodotto

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.

Grazie per averci aiutato a migliorare il nostro sito web. Il vostro feedback è stato inviato