missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ Pierce™ Renilla-Firefly Luciferase Dual Assay Kit

Simultaneously detect intracellular Renilla and Red Firefly luciferase activity in mammalian whole cell lysates.

Marca:  Thermo Scientific™ 16186

1196.24 EUR valido fino al 2024-12-31
Usa il codice promo "21651" per avere il tuo prezzo promozionale.


 vedi altre versioni di questo prodotto

Codice prodotto. 12201692

  • 1574.00€ / Pezzo
Spedizione stimata: 13-01-2025
per visualizzare lo stock disponibile
Esplora altre offerte speciali
Aggiungi al carrello
Questo articolo non è restituibile. Consulta la politica di reso

Descrizione

Descrizione

The Thermo Scientific™ Pierce Renilla-Firefly Luciferase Dual Assay Kit provides the necessary reagents to simultaneously detect intracellular Renilla and Red Firefly luciferase activity in mammalian whole cell lysates.

The Pierce Renilla-Firefly Luciferase Dual Assay Kit is a highly sensitive assay that allows for the simultaneous detection of Green Renilla and Red Firefly luciferase activity. Green Renilla luciferase acts as an experimental reporter with constitutively active red firefly as a normalization control. This reporter-and-control combination enables simultaneous monitoring of experimental reporter and control luciferase activities in a single-read assay without the need for two-step addition of substrate reagents or quenching. The assay working solution contains substrates for both luciferases, and the reactions occur simultaneously with flash-type kinetics. The resulting luminescent signals are spectrally resolvable using filters. In a single sample, researchers can assay transcriptional activity of regulatory elements, signal transduction pathways, and effects of activators or inhibitors.

Highlights:

  • Simultaneous – concurrent, filter-based, wavelength-separated detection of two luciferase activities

  • Sensitive – measure Green Renilla and red firefly luciferase activities in the same sample

  • Fast – no quenching step required, unlike in traditional sequential dual assays

  • Multiplex – capable of quantitating two cellular activities in the same sample(s)

Includes:

Cell lysis buffer, reaction buffer, and substrates coelenterazine and D-luciferin

Requires:

Green Renilla and Red Firefly luciferase reporters; Filter sets at 525nm±20nm for Green Renilla Luc and 615 to 675nm for Red Firefly Luc. Luminometer or other instrument capable of monitoring luminescence, such as Thermo Scientific Luminoskan Ascent and Varioskan Flash Microplate Readers; Injector required for assessing more than 24 wells at a time.

Recommended for:

Study two regulatory elements at the same time; Monitor two signaling pathways simultaneously; Enable studying more than one target per screen (e.g. off-target effects)

TRUSTED_SUSTAINABILITY
Specifica

Specifica

Assay Kit
1000 Dual Luciferase Assays
Sufficient For: 1000 dual-luciferase assays in microplate wells
• Renilla-Firefly Dual Assay Buffer, 50 mL (store at 4°C)
• 100X Coelenterazine, 0.5 mL (store at -80°C)
• D-Luciferin, 30 mg (store at 4°C)
• Luciferase Cell Lysis Buffer (2X), 60 mL (store at room temperature)

Upon receipt, store kit at -80°C, or store individual components as indicated above.
Mammalian Cells
Luminometer (Microplate)
Enzyme Labeled
Enhanced Chemiluminescence
Pierce™
Luciferase, Firefly Luciferase, Green Renilla Luciferase
1000 Reaction Kit
Reporter Enzyme, Luciferase Reporter Assay
Bioluminescence
384-well plate, 96-well plate
Chemical Substrate
Luciferase Substrate
Coelenterazine, D-Luciferin
Suggerimenti di prodotto

Suggerimenti di prodotto

Videos
SDS
Documenti

Documenti

Certificati
Offerte speciali

Offerte speciali

Correzione del contenuto del prodotto

Fornite il vostro feedback sul contenuto del prodotto compilando il modulo sottostante.

Titolo del prodotto

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.

Grazie per averci aiutato a migliorare il nostro sito web. Il vostro feedback è stato inviato

For Research Use Only. Not for use in diagnostic procedures.